<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-15 21-27-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 50 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 4.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
8 kHz 73 kHz 16753 6,3272
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
5,5 dBr 6,09 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 0 2 21:27, 15.07.2024
RT
"RTL VIVRENSEMBLE "
AF EON
95.3, 99.8, 100.4, 101.3, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 105.0, 105.1, 106.0 MHz -
FM Scope Station: 104.20 MHz, signal: 5/5 (50 dBuV) Max at: 73 kHz MIN: 8 kHz % above 75 kHz: 6,3272 Acquired: 2024/07/15 21:26:47 Total samples: 16753 Equivalent time: 0:13:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,4 dBr MIN: 5,5 dBr AVE: 6,09 dBr % above 11,2 dBr: 0,0 Last value: 5,6 dBr (2024/07/15 21:26:47) Station: 104.20 MHz, signal: 5/5 (50 dBuV) 21:14 21:16 21:18 21:20 21:22 21:24 21:26 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality